Line Items: 0 Total Items: 0 Sub Total: $0.00 |
|
CURRENT
SHOPPING
CART STATUS
▪▪▪▪▪▪▪▪▪▪▪▪▪▪▪▪▪▪▪▪▪▪▪▪▪▪▪▪▪▪▪▪▪▪
Applicable Tax and Freight Charge will be added to Final Invoice.
|
|
|
|
|
|
SubSurface LC-2500 Leak
Noise Correlator |
|
Top |
 |
- Ruggedly Built
and Weather Tight
- Best Sensors in
the Business
- Great Sensors,
Powerful Radios and Fast Processors
|
|
 |
 |
|
High Sensitivity, small diameter Black
sensors standard for metal pipes and AC Mains |
Low Frequency Red Sensors for PVC pipes,
poly services and large mains |
| |
|
LEAK CORRELATOR
OVERVIEW

The SubSurface LC-2500 Leak Noise Correlator is very lightweight and
compact, yet it offers full capabilities for programming many different
pipe materials and pipe diameters. View data on suspect leaks in
the field or download the data to PC for further analysis.
Ruggedly built and weather resistant with an industry best, a 5 year -
"NO BULL" warranty. Pollardwater.com trains and supports you
through the process - making sure those who use the machine are properly
trained and ready to use the LC-2500.
Great Sensors, powerful radios and fast
processing of sounds make the LC-2500 truly the best performing
correlator for the money. It all starts at the sensors - high
sensitivity, small diameter sensors that work for metal and A/C water
mains and optional low frequency red sensors for PVC pipe or plastic
service mains. The sound then goes from the sensors to powerful
pre amp/transmitters with radios that go over hills and around buildings
(500 milliWatts output sends signals up to 3,500 feet in each direction)
to a powerful main processor unit that displays the correlation picture.
How it Works
The LC-2500 correlates the sounds found between two sensors that you
place either directly on the pipe or on valves, hydrants, or anything
else touching the pipe. After inputting the type of pipe and the
distance between the sensors, the LC-2500 listens and correlates the
sound it hears. If there is a leak, the sensors will pick up the
noise created by the leak and send the data from both sensors back to
the main processing unit where it will process thousands of data points
into a graph showing the correlation or that data. A spike on the
graph (which might be created by the "hissing" of a leak) would be a
good indicator of a suspect leak.

The Main Processor Unit and the
Pre-Amps/Transmitters can operate in rain storms, subzero temperatures,
and direct sunlight for hours. The new LC-2500 sensors are very
small in diameter and totally submersible - great for correlations using
valves. Runs all day on standard or rechargeable batteries.
The LC-2500 comes standard with Black
Sensors that are used for standard metal and AC pipe. Optional Red
Sensors are for "Low Frequency" applications on PVC pipe, poly services
or very large mains.
Basic Systems start at $19,950 for iron
pipe sensors and $22,900 when you add in the plastic sensors. For
PC 's we offer the latest and best portable from Dell or HP -
preconfigured and ready to use. Please call customer service at
800-437-1146 (U.S.), or 516-746-0842 (All others), or
request a quote for
ordering. |
| |
 |
In PIPE DATA INPUT,
choose the pipe material, diameter, and length for every section of pipe
between the two sensors. Up to six pipe sections can be entered
(always in order from the "Blue" sensor to the "Red" Sensor) |
| |
 |
In FFT ANALYSIS,
the user can examine the sound signals form both sensors from 0 to 5000
Hz. The FFT function can automatically select the high and low
filters if AUTO is chosen in FILTER SETUP. |
| |
 |
In CORRELATION,
the correlation "picture" indicates whether the leak sounds are clearly
heard at both sensors. The distance to the leak and the filter
settings are displayed. |
| |
|
LC-2500
CORRELATOR SPECIFICATIONS

The LC-2500 System Includes:
-
LC-2500 Main Processor Unit
-
Blue Pre-Amplifier with Radio Communication
-
Red Pre-Amplifier with Radio Communication
-
Two High Sensitivity, Small Diameter Sensors for Metal Pipes
-
Aviation Grade Headphones
-
Instruction Manual and Field Guide
-
Two "Heavy Duty" Plastic Carrying Cases
Optional Accessories:
-
Two Red Sensors for PVC Pipes, "Poly" Services, and Large Diameter Mains
-
LC-2500 Windows PC Software (for downloading)
Back to Top
|
MAIN PROCESSOR UNIT |
| Operating Temperature
Range |
-10 to 50 degrees C |
| Applicable Standard |
IP52 (weather tight) |
| External Dimensions |
7.8" x 4.0" x 9.9"
W x D x H |
| Weight |
Approximately 6.8 lbs
(with batteries) |
| Battery |
4 "D" Cell |
| Continuous Operating
Time |
13 hours minimum (at
20 degrees C, backlight OFF) |
| Minimum Operating
Voltage |
4.2 V |
| Input |
Radio or Cable |
| Display |
Dot matrix LCD |
| Operation |
Polarity correlation |
| Td Range |
±50 ms, ±100 ms, ±300
ms, ±400 ms, ±800 ms, ±1600 ms or automatic setting |
| Time Resolution |
µs 25 (in ±50 ms
range), µs 50 (in ±100 ms range), µs 100 (in ±200 ms range), µs 200
(in ±400 ms range), µs 400 (in ±800 ms range), µs 800 (in ±1600 ms
range) |
| Filter Range |
THRU, 80 Hz to 5,000
Hz (4 low and 4 high) |
| Notch Filter |
OFF, 50 Hz, 60 Hz |
| Auto Filter |
Automatically selected
from FFT operation |
| Data Memory |
100 correlations |
| FFT Monitor |
1 kHz, 2.5 kHz, 5 kHz
(common to both channels) |
| Sound Memory |
For 16 seconds |
| External Interface |
RS-232C |
| |
|
|
RED AND BLUE
PRE-AMPLIFIERS |
| Operating Temperature
Range |
-10 to 50 degrees C |
| Applicable Standard |
IP52 (weather tight) |
| External Dimensions |
5.9" x 4.2" x 14.5" W
x D x H |
| Weight |
Approximately 6.3 lbs
(with batteries) |
| Battery |
6 "D" Cell (Standard
or Rechargeable) |
| Continuous Operating
Time |
10 hours minimum (at
20 degrees C, backlight OFF) |
| Minimum Operating
Voltages |
6.0 V |
| INPUT |
| Input Frequency Range |
20 Hz to 4 kHz (at
THRU filter setting), 100 Hz to 5 kHz (at STD filter setting) |
| Input Sensitivity |
50 micro V, max |
| Signal to Noise Ratio |
35 dB, min |
| RADIO COMMUNICATION
SYSTEM |
| Output Frequency |
UHF under approved
frequency |
| Modulation |
Direct Frequency
modulation |
| Output Power |
0.5 W (500 mW) |
| Output Impedance |
50 ohms |
| |
|
|
SENSORS |
| Type |
Piezoelectric pick-up |
| Voltage Sensitivity |
2.5 V/g (peak) |
| Applicable Standard |
IP68 (water-proof) |
| Drop Resistance |
3 feet (asphalt) |
| External Dimensions |
1.2" diameter x 5.1"
high |
| Weight |
15 ounces each |
| Power Supply System |
3-wire |
| Output Impedance |
100 ohms, max |
| Power Supply Voltage |
5.0 V |
| |
Back to Top |
|
|
|